During pulmonary function testing (PFT), pa¬tients tend to tilt from upright to leaning forward position. The influence of torso movement on EIT chest exa-minations is unknown. We studied this effect in heal-thy subjects and patients with pulmonary diseases and found significant position-dependent changes in end-expi¬ra¬tory impedance that may impact EIT findings during PFT.